View full size

Cooling Tower LRC

Post on 12-06-2013 05:05:00 AM - 6951 Views

Rating : 54 notes 1 2 3 4 5

Share :


CONSTRUCTION AND FEATURES:

1.1 Inlet louver & side plate:
PVC inlet louvers and FRP side plates are anti-acid, anti-alkaline, weather-proof, anti-corrosive and resistant to Ultra-Violet, none-twisted and non-deformed.

1.2 Water Sump:
The water sump is made of FRP material and externally supported with hot-dipped-galvanized steel. The piping of water sump includes outlet water, autofiller pipe, quick filler pipe, over-flow pipe and drain pipe. The stainless steel suction strainer is installed on outlet pipe to blockade the alien objects from entering. The basin partitions can be additionally installed for multiple cells so that the tower can be cleaned or maintained for the individual cell or partially, without affecting the operation of the whole system.
 
1.3 Plenum:
The cross flow type’s heat exchanging process is applied. The direct contact between vertical air from both sides and the falling water from hot water basin occurs inside the PVC filling so that the heat can be rejected from the tower by the fan. The access door and walkway equipped inside the tower are to insure the convenience of maintenance and cleaning.

1.4 Motor:
Outdoor TEFC motors are applied

1.5 Driving Unit:
The axial fan design is applied and can be adjusted based on actual operation of air volume. The speed reducer is driven with multi-belts to insure that there is larger contact area, low vibration and smooth transmission. The belts are protected with FRP casing so that they are not wetted and not gliding.

1.6 Filling:
PVC fillings are vacuum-formed and glued together on nipple ends so that there is adequate space to avoid scaling and clogging. Thus, the water can be evenly distributed to insure good heat exchanging of cooling towers. Each layer of filling block has steel supporters to prevent from deforming and falling off. The bottom are designed with suspened supporters to avoid depositing various objects and scaling so that cooling towers can be ease of maintenance and cleaning.

1.7 Distribution System:
Hot water basins are installed on tow sides of tower and distribution water is gravitstionally falling into tower with low water pressure. This design leads the water to spread into the fillings evenly and achieve the best efficiency of heat exchanging. FRP distribution box inside can lower the inlet water pressure to prevent the water from splashing.

1.8 Float Valve Ass’y:
Bronze float valve ass’y is equipped inside the water basin and adjustable for controlling normal water level during operation.

1.9 Water Eliminators:
The Z type water eliminators placed on the top of filling have best water elimination efficiency and are capable to save the make up water by reducing drift loss.

TẢI FILE NÀY VỀ MÁY
( VÀO ĐÂY NẾU KHÔNG XEM ĐƯỢC )

http://liangchi.com.vn/uploads/cooling-tower/2013_06/catalogue-lrc-anhnew.pdf

TẢI FILE NÀY VỀ MÁY
( VÀO ĐÂY NẾU KHÔNG XEM ĐƯỢC )

http://liangchi.com.vn/uploads/cooling-tower/2013_10/bang-huong-dan-su-dung-lrce.pdf
KHÔNG CÓ DỮ LIỆU
http://liangchi.com.vn